  • SFP+ DWDM Optical Transceiver, 20KM Reach

SFP+ DWDM Optical Transceiver, 20KM Reach

Availability:

Collections: Alcatel lucent, SFP+ Transceivers

Vendor: skyward

Tags: —

DWDM-SFP+-20-XX

SFP+ DWDM Optical Transceiver,20KM Reach

 

Features

►Compliant with SFF-8413 and IEE802.3ae

►Suitable for use in 100GHz channel spacing DWDM systems

►Data rate selectable ≤4.25Gbps or 9.95Gbps to 10.3Gbps bit rates

►Cooled EML transmitter and PIN receiver

►link length up to 20km

►Low Power Dissipation 1.5W Maximum

►-5ºC to 70ºC Operating Case Temperature

►Single 3.3V power supply

►Diagnostic Performance Monitoring of module temperature, supply Voltages, laser bias current, transmit optical power, receive optical power

►RoHS compliant and lead free

 

Applications

►10GBASE 20KM (with/without FEC)

►10G Fiber Channel (with/without FEC)

 

Description

  SFP+ER DWDM Transceiver is designed for 10GBASE 20KM, and 8.5G/10G Fiber- Channel applications.

    The transceiver consists of two sections: The transmitter section incorporates a colded EML laser. And the receiver section consists of a PIN photodiode integrated with a TIA. All modules satisfy class I laser safety requirements. Digital diagnostics functions are available via a 2-wire serial interface, as specified in SFF-8472, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage.

 

Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage

Vcc

-0.5

3.8

V

Storage Temperature

Tst

-40

85

ºC

Relative Humidity

Rh

0

85

%

 

Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Supply Voltage

Vcc

3.13

3.3

3.47

V

Supply current

Icc

 

360

450

mA

Operating Case temperature

Tca

-5

-

70

ºC

Module Power Dissipation

Pm

-

1.2

1.5

W

Notes:

[1] Supply current is shared between VCCTX and VCCRX.

[2] In-rush is defined as current level above steady state current requirements.

 

Transmitter Specifications – Optical

Parameter

Symbol

Min

Typical

Max

Unit

Center Wavelength (SOL)△

lc

lc -25

lc

lc +25

pm

Center Wavelength (EOL)▲

lc

lc -100

lc

lc+100

pm

Optical OMA Power

Pom

-1.7

 

 

dBm

Side Mode Suppression Ratio

SMSR

30

-

-

dB

Optical Transmit Power (disabled)

PTX_DISABLE

-

-

-30

dBm

Extinction Ratio

ER

8.2

 

-

dB

RIN21OMA [1]

 

 

 

-128

dB/Hz

Optical Return Loss Tolerance

 

 

 

21

dB

Notes:

[1] RIN measurement is made with a return loss at 21 dB.

△Laser- Start of Life

▲Laser End of life

Transmitter Specifications – Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Data Rate

Mra

-

10.3

11.3

Gbps

Input differential impedance

Rim

-

100

-

Ω

Differential data Input

VtxDIFF

120

-

850

mV

Transmit Disable Voltage

VD

2.0

-

Vcc3+0.3

V

Transmit Enable Voltage

Ven

0

-

+0.8

V

Transmit Disable Assert Time

Vn

-

-

100

us

 

Receiver Specifications – Optical

Parameter

Symbol

Min

Typical

Max

Unit

Input Operating Wavelength

λ

1260

-

1620

nm

Average receive power

 

-

-

-1.0

dBm

Receiver sensitivity in OMA

 

-

-

-14.1

dBm

Stressed receiver sensitivity  in OMA[1]

 

 

 

 

-11.3

dBm

Maximum Input Power

RX-overload

-

-

-1

dBm

Reflectance

Rrx

-

-

-27

dB

Loss of Signal Asserted

 

-25

-

-

dBm

LOS De-Asserted

 

-

-

-16

dBm

LOS Hysteresis

 

0.5

-

-

dB

Notes:

[1] Measured with conformance test signal for BER = 10–12. The stressed sensitivity values in the table are for system level BER measurements which include the effects of CDR circuits. It is recommended that at least 0.4 dB additional margin be allocated if component level measurements are made

without the effects of CDR circuits.

 

Receiver Specifications – Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Data Rate

Mra

-

10.3

11.3

Gbps

Differential Output Swing

Vout P-P

350

-

850

mV

Rise/Fall Time

Tr / Tf

24

-

-

ps

Loss of Signal –Asserted

VOH

2

-

Vcc3+0.3-

V

Loss of Signal –Negated

VOL

0

-

+0.4

V

 

        Figure1.Electrical Pin-out Details

 

Pin Descriptions

Pin

Symbol

Name/Description

1

VEET [1]

Transmitter Ground

2

Tx_FAULT [2]

Transmitter Fault

3

Tx_DIS   [3]

Transmitter Disable. Laser output disabled on high or open

4

SDA [2]

2-wire Serial Interface Data Line

5

SCL [2]

2-wire Serial Interface Clock Line

6

MOD_ABS [4]

Module Absent. Grounded within the module

7

RS0 [5]

RS0 for Rate Select: Open or Low = Module supports ≤4.25Gbps

High = Module supports 9.95 Gb/s to 10.3125 Gb/s

8

RX_LOS [2]

Loss of Signal indication. Logic 0 indicates normal operation

9

RS1 [5]

No connection required

10

VEER [1]

Receiver Ground

11

VEER [1]

Receiver Ground

12

RD-

Receiver Inverted DATA out. AC Coupled

13

RD+

Receiver DATA out. AC Coupled

14

VEER [1]

Receiver Ground

15

VCCR

Receiver Power Supply

16

VCCT

Transmitter Power Supply

17

VEET [1]

Transmitter Ground

18

TD+

Transmitter DATA in. AC Coupled

19

TD-

Transmitter Inverted DATA in. AC Coupled

20

VEET [1]

Transmitter Ground

Notes:

[1] Module circuit ground is isolated from module chassis ground within the module.

[2].should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15Vand 3.6V.

[3]Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VccT inside the module.

[4]Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to Vcc_Host with a resistor in the range 4.7 kΩ to10 kΩ.Mod_ABS is asserted “High” when the SFP+ module is physically absent from a host slot.

[5] RS0 and RS1 are module inputs and are pulled low to VeeT with > 30 kΩ resistors in the module.

 

C-band λc Wavelength Guide

ITU Channel

Product Code

Frequency(THz)

Wavelength

ITU Channel

Product Code

Frequency(THz)

Wavelength

17

191.7

1563.86

40

194.0

1545.32

18

191.8

1563.05

41

194.1

1544.53

19

191.9

1562.23

42

194.2

1543.73

20

192.0

1561.42

43

194.3

1542.94

21

192.1

1560.61

44

194.4

1542.14

22

192.2

1559.79

45

194.5

1541.35

23

192.3

1558.98

46

194.6

1540.56

24

192.4

1558.17

47

194.7

1539.77

25

192.5

1557.36

48

194.8

1538.98

26

192.6

1556.55

49

194.9

1538.19

27

192.7

1555.75

50

195.0

1537.40

28

192.8

1554.94

51

195.1

1536.61

29

192.9

1554.13

52

195.2

1535.82

30

193.0

1553.33

53

195.3

1535.04

31

193.1

1552.52

54

195.4

1534.25

32

193.2

1551.72

55

195.5

1533.47

33

193.3

1550.92

56

195.6

1532.68

34

193.4

1550.12

57

195.7

1531.90

35

193.5

1549.32

58

195.8

1531.12

36

193.6

1548.51

59

195.9

1530.33

37

193.7

1547.72

60

196.0

1529.55

38

193.8

1546.92

61

196.1

1528.77

39

193.9

1546.12

 

 

 

 

 

 

 

 

 

Figure2. Host Board Power Supply Filters Circuit

 

 

 

Figure3. Host-Module Interface

 

Figure6. Mechanical Specifications

 

 

 

Ordering information

Part Number

Product Description

DWDM-SFP+-20

ITU Grid 17~61, 10Gbps, DWDM SFP+ 20km, -5ºC ~ +70ºC

DWDM-SFP+-20I

ITU Grid 17~61, 10Gbps, DWDM SFP+ 20km, -40ºC ~ +85ºC

 

 

About US

Skyward telecom always take honesty as our motto and provide network security & computer asset management solutions to users in over 80 countries, which has been recognized by the market.

Hot Searches

  • RRU
  • Baseband Unit (BBU)
  • Nokia Telecom Boards
  • ZTE Telecommunication Devices
  • Ericsson Cables

CONTACT US

HongKong: 11th Floor, The Center, 99 Queen's Road Central, Central, Hong Kong.

8613556898274 support@skywardtel.com

Newsletter

You have successfully subscribed!

Join our mailing list

©Skyward Telecom. Powered by Shopify