Skyward Telecom
WhatsApp: +8613556898274

Menu

  • Products
    • Accessories

      • Telecom Cables
      • Power Supplies
      • Fans
      • AOC / DAC
      • Connectors
      • Bracket

      Telecommunication

      • Alcatel Devices
      • Nokia Devices
      • Ericsson Devices
      • Other Devices

      Optical Transceivers

      • SFP Transceivers
      • SFP+ Transceivers
      • SFP28 Transceivers
      • QSFP+ Transceivers
      • QSFP28 Transceiver

  • Brands
  • NEWS
  • About Us
  • CONTACT US
  • Home
  • 1.25Gbps Tx1310/Rx1490nm 10km SFP Bi-Directional Transceiver

1.25Gbps Tx1310/Rx1490nm 10km SFP Bi-Directional Transceiver

Availability:

Collections: SFP Transceivers

Vendor: skyward

Tags: —

Features

  • Single Mode bi-directional Transmission
  • SFP Multi-source Package with LC Receptacle
  • Up to 1.25Gb/s Data Links
  • Hot-Pluggable Capability
  • Up to 10 km on 9/125μm SMF
  • Single +3.3V Power Supply
  • Built-in WDM
  • Isolation > 30dB, Cross Talk < -45dB
  • Monitoring Interface Compliant with SFF-8472
  • Metal Enclosure, Excellent EMI & ESD Protection
  • Compliant with Specifications for IEEE802.3Z
  • Compliant with Bellcore TA-NWT-000983
  • Eye Safety Designed to Meet Laser Class1, Compliant with IEC60825-1
  • RoHS Compliant

Applications

  • Gigabit Ethernet
  • Fiber Channel
  • WDM Application 

Description

  The Bi-Directional transceiver is a high performance, cost effective module ,which is compliant with LC Optics interface with built in WDM for Bi-Directional serial optical data communication applications. This module is designed for Single-Mode single fiber, operates at the normal wavelength of 1310/1490nm.

Standard AC coupled CML for high speed signal and LVTTL control and monitor signals.

The transmitter section incorporates FP and driver IC with temperature compensation and automatic power control circuit, which make the transmitter section output power and Extinction ration stabled in operation temperature.

The receiver section incorporates an efficient InGaAs photodiode and transimpedance with AGC for wide dynamic range.

  • Absolute Maximum Ratings

Parameter

Symbol

Min.

Typical

Max.

Unit

Storage Temperature

TS

-40

 

+85

°C

Supply Voltage

VCCT, R

-0.5

 

4

V

Relative Humidity

RH

0

 

85

%

Case Operating Temperature

Industrial

Top

-40

 

85

C

Extended

-5

 

85

Commercial

0

 

70

 

  • Recommended Operating Environment:

Parameter

Symbol

Min.

Typical

Max.

Unit

Case operating Temperature

Industrial

TC

 

 

 

 

Extended

 

 

 

 

Commercial

0

 

+70

°C

Supply Voltage

VCCT, R

3.0

 

3.6

V

Power Supply Rejection

 

100

 

 

mVP-P

 

  • Electrical Characteristics(TOP = 0 to 70 °C, VCC = 3.0 to 3.60 Volts)

Parameter

Symbol

Min.

Typical

Max.

Unit

Note

Supply Voltage

Vcc

3.0

3.30

3.60

V

 

Supply Current

Icc

 

160

280

mA

 

Inrush Current

Isurge

 

 

Icc+30

mA

 

Maximum Power

Pmax

 

 

1.0

W

 

Transmitter Section:

 

Input differential impedance

Rin

90

100

110





Single ended data input swing

Vin PP

200

 

1200

mVp-p

 

Transmit Disable Voltage

VD

Vcc – 1.3

 

Vcc

V

2

Transmit Enable Voltage

VEN

Vee

 

Vee+ 0.8

V

 

Transmit Disable Assert Time

Tdessert

 

 

10

us

 

Receiver Section:

 

Single ended data output swing

Vout,pp

300

 

1000

mv

3

Data output rise time

tr

 

 

150

ps

4

Data output fall time

tf

 

 

150

ps

4

LOS Fault

Vlosfault

Vcc – 0.5

 

VCC_host

V

5

 

 

LOS Normal

Vlos norm

Vee

 

Vee+0.5

V

5

Power Supply Rejection

PSR

100

 

 

mVpp

6

Deterministic Jitter Contribution

RXΔDJ

 

 

51.7

ps

7

Total Jitter Contribution

RXΔTJ

 

 

122.4

ps

 

 

Note:

  1. AC coupled.
  2. Or open circuit.
  3. Into 100 ohm differential termination.
  4. 20 – 80 %
  5. LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.
  6. All transceiver specifications are compliant with a power supply sinusoidal modulation of 20 Hz to 1.5MHz up to specified value applied through the power supply filtering network shown on page 23 of the Small Form-factor Pluggable (SFP) Transceiver Multi-Source Agreement (MSA), September 14, 2000.
  7. Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ and . DJ.

 

  • Optical Parameters(TOP = 0 to 70 °C, VCC = 3.0 to 3.60 Volts)

Parameter

Symbol

Min.

Typical

Max.

Unit

Note

Transmitter Section:

Center Wavelength

λc

1270

1310

1360

nm

1

Spectral Width

σ

 

 

3

nm

 

Optical Output Power

Pout

-9

 

-3

dBm

2

Optical Rise/Fall Time

tr / tf

 

 

160

ps

3

Extinction Ratio

ER

9

 

 

dB

 

Deterministic Jitter Contribution

TXΔDJ

 

 

56.5

ps

4

Total Jitter Contribution

TXΔTJ

 

 

119

ps

 

Eye Mask for Optical Output

Compliant with Eye Mask Defined in IEEE 802.3 standard

 

Relative Intensity Noise

RIN

 

 

-120

dB/Hz

 

Receiver Section:

 

Optical Input Wavelength



1480

1490

1500

nm

 

Optical Input Power

Pin

-23

 

-3

dBm

5.6

Receiver Reflectance

 

12

 

 

dB

 

Receiver Overload

Pol

 

 

-3

dBm

5.6

RX Sensitivity

Sen

 

 

-23

dBm

5.6

RX_LOS Assert

LOS A

-34

 

 

dBm

 

RX_LOS Deassert

LOS D

 

 

-24

dBm

 

RX_LOS Hysteresis

LOS H

 

2

2.5

dB

 

General Specifications

Data Rate

BR

1062

 

1250

Mb/s

 

Bit Error Rate

BER

 

 

10-12

 

 

Max. Supported Link Length on 9/125μm SMF@1.25G

LMAX

 

 

10

km

7

Total System Budget

LB

14

 

 

dB

8

Note

  1. Also specified to meet curves in FC-PI 13.0 Figures 18 and 19, which allow trade-off between wavelength spectral width.
  2. Class 1 Laser Safety per FDA/CDRH and EN (IEC) 60825 regulations.
  3. Unfiltered, 20-80%. Complies with IEEE 802.3 (Gig. E), FC 1x and 2x eye masks when filtered.
  4. Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ and . DJ.
  5. Measured with conformance signals defined in FC-PI 13.0 specifications.
  6. Measured with PRBS 27-1 at 10-12 BER
  7. Dispersion limited per FC-PI Rev. 13
  8. .Attenuation of 0.45 dB/km is used for the link length calculations. Distances are indicative only. Please refer to the Optical Specifications in Table IV to calculate a more accurate link budget based on specific conditions in your application.

 

  • Digital Diagnostic Monitor Characteristics

The following digital diagnostic characteristics are defined over the Recommended Operating Environment unless otherwise specified. It is compliant to SFF8472 Rev10.2 with internal calibration mode. For external calibration mode please contact our sales stuff..

Parameter

Symbol

Min.

Max.

Unit

Temperature monitor absolute error

DMI_Temp

-3

3

degC

Laser power monitor absolute error

DMI_TX

-3

3

dB

RX power monitor absolute error

DMI_RX

-3

3

dB

Supply voltage monitor absolute error

DMI_VCC

-0.1

0.1

V

Bias current monitor absolute error

DMI_Ibias

-10%

10%

mA

 

  • Serial ID Memory Contents:

Data Address

Length

(Byte)

Name of

Length

Description and Contents

Base ID Fields

0

1

Identifier

Type of Serial transceiver (03h=SFP)

1

1

Reserved

Extended identifier of type serial transceiver (04h)

2

1

Connector

Code of optical connector type (07=LC)

3-10

8

Transceiver

Gigabit Ethernet 1000Base-BX

11

1

Encoding

8B10B (01h)

12

1

BR,Nominal

Nominal baud rate, unit of 100Mbps

13

1

Reserved

(0000h)

14

1

Length(9um,km)

Link length supported for 9/125um fiber, units of km

15

1

Length(9um)

Link length supported for 9/125um fiber, units of 100m

16

1

Length(50um)

Link length supported for 50/125um fiber, units of 10m

17

1

Length(62.5um)

Link length supported for 62.5/125um fiber, units of 10m

18

1

Length(Copper)

Link length supported for copper, units of meters

19

1

Reserved

 

20-35

16

Vendor Name

SFP vendor name:

36

1

Reserved

 

37-39

3

Vendor OUI

SFP transceiver vendor OUI ID

40-55

16

Vendor PN

Part Number: “BTxxxx” (ASCII)

56-59

4

Vendor rev

Revision level for part number

60-61

2

Wavelength

Laser wavelength

62

1

Reserved

 

63

1

CCID

Least significant byte of sum of data in address 0-62

Extended ID Fields

64-65

2

Option

Indicates which optical SFP signals are implemented(001Ah = LOS, TX_FAULT, TX_DISABLE all supported)

66

1

BR, max

Upper bit rate margin, units of %

67

1

BR, min

Lower bit rate margin, units of %

68-83

16

Vendor SN

Serial number (ASCII)

84-91

8

Date code

Manufacturing date code

92

1

Diagnostic Type

Diagnostics

93

1

Enhanced Options

Diagnostics

 

93

1

Enhanced Options

Diagnostics

94

1

SFF-8472

Diagnostics

95

1

CCEX

Check code for the extended ID Fields (addr. 64 to 94)

Vendor Specific ID Fields

96-127

32

Readable

Vendor specific date, read only

 

  • Diagnostics Memory Contents(A2h):

Data Address

Length

(Byte)

Name of Length

Description and Contents

Diagnostic and control/status fields

0-39

40

A/W Thresholds

Diagnostic Flag Alarm and Warning Thresholds

40-55

16

Unallocated

 

56-91

16

Ext Cal Constants

Diagnostic calibration constants for optional External Calibration

92-94

3

Unallocated

 

95

1

CC_DMI

Check code for Base Diagnostic Fields (addresses 0 to 94)

96-105

10

Diagnostics

Diagnostic Monitor Data (internally or externally calibrated)

106-109

4

Unallocated

 

110

1

Status/Control

Optional Status and Control Bits

111

1

Reserved

Reserved for SFF-8079

112-113

2

Alarm Flags

Diagnostic Alarm Flag Status Bits

114-115

2

Unallocated

 

116-117

2

Warning Flags

Diagnostic Warning Flag Status Bits

118-119

2

Ext Status/Control

Extended module control and status bytes

General use fields

120-127

8

Vendor Specific

Vendor specific memory addresses

128-247

120

User EEPROM

User writable non-volatile memory

248-255

8

Vendor Control

Vendor specific control addresses

 

Ordering information

Part Number

Product Description

BT-OC24-10A+

1.25Gbps Tx1310/Rx1490nm 10km LC DDM SFP 0°C~+70°C

BT-OC24-10AS+

1.25Gbps Tx1310/Rx1490nm 10km SC DDM SFP 0°C~+70°C

BT-OC24-10AI+

1.25Gbps Tx1310/Rx1490nm 10km LC DDM SFP -40°C~+85°C

BT-OC24-10ASI+

1.25Gbps Tx1310/Rx1490nm 10km SC DDM SFP -40°C~+85°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

About US

Skyward telecom always take honesty as our motto and provide network security & computer asset management solutions to users in over 80 countries, which has been recognized by the market.

Hot Searches

  • RRU
  • Baseband Unit (BBU)
  • Nokia Telecom Boards
  • ZTE Telecommunication Devices
  • Ericsson Cables

CONTACT US

HongKong: 11th Floor, The Center, 99 Queen's Road Central, Central, Hong Kong.

8613556898274 support@skywardtel.com

Newsletter

You have successfully subscribed!

Join our mailing list

©Skyward Telecom. Powered by Shopify