{"title":"800G Optical Transceivers","description":null,"products":[{"product_id":"800g-osfp-vr8-2xvr4-optical-transceiver","title":"800GBASE-VR8 OSFP Transceiver, 850nm, Dual MPO-12 APC, 50m OM4 OM5 MMF for AI Cluster","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.7;color:#222;max-width:960px;margin:0 auto;\"\u003e\n\u003cp style=\"font-size:18px;\"\u003eOur 800G OSFP VR8 (2×VR4) optical transceiver is a high-performance multi-mode parallel module compliant with 800GBASE-VR8 and OSFP MSA standard, supporting 800G full rate or breakout to 2×400G VR4, designed for short-reach AI cluster links over OM4\/OM5 multi-mode fiber.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:24px;\"\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eItem\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eSpecification\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eForm Factor\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eSingle-port OSFP-RHS\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eData Rate\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e800Gbps (8×106.25G PAM4), breakout support 2×400G VR4\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eWavelength\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e850nm, VCSEL\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eFiber Type\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eMulti Mode Fiber (OM4 \/ OM5 MMF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eReach\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eUp to 50m over OM4\/OM5 MMF\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eDual MPO-12 APC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eWorking Temp\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e0℃ ~ 70℃\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003ePower Consumption\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e≤17W (final value subject to supplier datasheet)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eDiagnostic\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eDDM \/ Digital Diagnostics Monitoring\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eCompatibility List\u003c\/h3\u003e\n\u003cp\u003eDesigned for OSFP-RHS ports that accept generic MSA-compliant transceivers. For host adapters and switches, please confirm your firmware\/OS allows third-party optics and supports the VR8 profile before ordering. \u003cstrong\u003eNote: This parallel module is NOT compatible with Quantum series switches that use dual-port OSFP cages.\u003c\/strong\u003e Modules are programmed with standard 800GBASE-VR8 CMIS data.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eCore Advantages\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;margin:8px 0 24px;\"\u003e\n  \u003cli\u003e✅ Hot-pluggable single-port OSFP-RHS design\u003c\/li\u003e\n  \u003cli\u003e✅ Flexible working mode: 800G full rate or split into 2 independent 400G VR4 channels\u003c\/li\u003e\n  \u003cli\u003e✅ Strictly 100% tested before shipment, stable for AI cluster long-running\u003c\/li\u003e\n  \u003cli\u003e✅ Compliant with CMIS, 800GBASE-VR8 and OSFP MSA specifications\u003c\/li\u003e\n  \u003cli\u003e✅ RoHS compliant, optimized power consumption\u003c\/li\u003e\n  \u003cli\u003e✅ DDM function, real-time monitoring of temperature, TX\/RX power, voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;margin:8px 0 24px;\"\u003e\n  \u003cli\u003eAI GPU cluster, HPC high-density server interconnection\u003c\/li\u003e\n  \u003cli\u003e800G XDR InfiniBand and 800G Ethernet uplink\u003c\/li\u003e\n  \u003cli\u003eShort-reach rack-to-rack links inside data center\u003c\/li\u003e\n  \u003cli\u003eServer adapter uplink to compatible 800G OSFP ports (verify port type and whitelist before ordering)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What fiber cable should I use for 800G OSFP VR8?\u003c\/strong\u003e\u003cbr\u003e\nA: VR8 is a multi-mode parallel module. It requires OM4 or OM5 multi-mode fiber with dual MPO-12 APC patch cords, max reach 50m. Single-mode fiber and LC cables cannot work.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with NVIDIA ConnectX-8 adapters?\u003c\/strong\u003e\u003cbr\u003e\nA: It follows 800GBASE-VR8 standard with OSFP-RHS form factor. Compatibility depends on whether your adapter firmware allows third-party optics and recognizes the VR8 profile. Please check the host whitelist before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What connector does OSFP VR8 use?\u003c\/strong\u003e\u003cbr\u003e\nA: Dual MPO-12 APC (two MPO-12 ports). Please prepare matching dual MPO-12 multi-mode patch cords.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be plugged into Quantum series switches?\u003c\/strong\u003e\u003cbr\u003e\nA: No. This is a single-port OSFP-RHS module for host adapters. Quantum switches use dual-port OSFP modules, which are physically incompatible.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can VR8 interoperate with DR8 \/ SR8 modules?\u003c\/strong\u003e\u003cbr\u003e\nA: No. Both ends of one fiber link must use the same standard: VR8 to VR8 only.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Skyward Telecom","offers":[{"title":"Default Title","offer_id":53713042768170,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/4948\/9450\/files\/10_37828c1f-914d-44ff-ae18-97e2e5ca7429.webp?v=1795435353"},{"product_id":"800g-osfp-dr8-2xdr4-optical-transceiver","title":"800GBASE-DR8 OSFP Transceiver, 1310nm, Dual MPO-12 APC, 500m SMF for AI GPU Cluster","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.7;color:#222;max-width:960px;margin:0 auto;\"\u003e\n\u003cp style=\"font-size:18px;\"\u003eOur 800G OSFP DR8 (2×DR4) optical transceiver is a high-performance single-mode parallel module compliant with 800GBASE-DR8 and OSFP MSA standard, supporting 800G full rate or breakout to 2×400G DR4, designed for medium-reach AI cluster and data center links over single-mode fiber.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:24px;\"\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eItem\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eSpecification\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eForm Factor\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eSingle-port OSFP-RHS\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eData Rate\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e800Gbps (8×106.25G PAM4), breakout support 2×400G DR4\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eWavelength\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e1310nm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eFiber Type\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eSingle Mode Fiber (SMF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eReach\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eUp to 500m over SMF\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eDual MPO-12 APC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eWorking Temp\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e0℃ ~ 70℃\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f7f7f7;\"\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003ePower Consumption\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003e≤16.5W (final value subject to supplier datasheet)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;font-weight:bold;\"\u003eDiagnostic\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;padding:10px;\"\u003eDDM \/ Digital Diagnostics Monitoring\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eCompatibility List\u003c\/h3\u003e\n\u003cp\u003eDesigned for OSFP-RHS ports that accept generic MSA-compliant transceivers. For host adapters and switches, please confirm your firmware\/OS allows third-party optics and supports the DR8 profile before ordering. \u003cstrong\u003eNote: This parallel module is NOT compatible with Quantum series switches that use dual-port OSFP cages.\u003c\/strong\u003e Modules are programmed with standard 800GBASE-DR8 CMIS data.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eCore Advantages\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;margin:8px 0 24px;\"\u003e\n  \u003cli\u003e✅ Hot-pluggable single-port OSFP-RHS design\u003c\/li\u003e\n  \u003cli\u003e✅ Flexible working mode: 800G full rate or split into 2 independent 400G DR4 channels\u003c\/li\u003e\n  \u003cli\u003e✅ Strictly 100% tested before shipment, stable for AI cluster long-running\u003c\/li\u003e\n  \u003cli\u003e✅ Compliant with CMIS, 800GBASE-DR8 and OSFP MSA specifications\u003c\/li\u003e\n  \u003cli\u003e✅ RoHS compliant, optimized power consumption\u003c\/li\u003e\n  \u003cli\u003e✅ DDM function, real-time monitoring of temperature, TX\/RX power, voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;margin:8px 0 24px;\"\u003e\n  \u003cli\u003eAI GPU cluster, HPC high-density server interconnection\u003c\/li\u003e\n  \u003cli\u003e800G XDR InfiniBand and 800G Ethernet uplink\u003c\/li\u003e\n  \u003cli\u003eRack-to-rack, row-to-row links inside data center\u003c\/li\u003e\n  \u003cli\u003eServer adapter uplink to compatible 800G OSFP ports (verify port type and whitelist before ordering)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0b1220;border-left:6px solid #59AD35;padding-left:12px;margin:24px 0 12px;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What fiber cable should I use for 800G OSFP DR8?\u003c\/strong\u003e\u003cbr\u003e\nA: DR8 is a single-mode parallel module. It requires single-mode fiber with dual MPO-12 APC patch cords, max reach 500m. Multi-mode fiber cannot work.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with NVIDIA ConnectX-8 adapters?\u003c\/strong\u003e\u003cbr\u003e\nA: It follows 800GBASE-DR8 standard with OSFP-RHS form factor. Compatibility depends on whether your adapter firmware allows third-party optics and recognizes the DR8 profile. Please check the host whitelist before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What connector does OSFP DR8 use?\u003c\/strong\u003e\u003cbr\u003e\nA: Dual MPO-12 APC (two MPO-12 ports). Please prepare matching dual MPO-12 single-mode patch cords.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be plugged into Quantum series switches?\u003c\/strong\u003e\u003cbr\u003e\nA: No. This is a single-port OSFP-RHS module for host adapters. Quantum switches use dual-port OSFP modules, which are physically incompatible.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can DR8 interoperate with VR8 \/ SR8 modules?\u003c\/strong\u003e\u003cbr\u003e\nA: No. Both ends of one fiber link must use the same standard: DR8 to DR8 only.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Skyward Telecom","offers":[{"title":"Default Title","offer_id":53713135829290,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/4948\/9450\/files\/7_653f178c-e517-4038-86bd-a291b1e317af.webp?v=1795436064"},{"product_id":"800g-osfp-fr8-2xfr4-transceiver-2km","title":"800GBASE-FR8 OSFP Transceiver 2×400G FR4 Breakout, 2km OS2 SM, Dual LC for Twin-port OSFP Switches","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; color:#333; line-height:1.6;\"\u003e\n\u003ch2 style=\"color:#222; border-bottom:1px solid #eee; padding-bottom:8px;\"\u003e800G OSFP FR8 (2×FR4) Optical Transceiver Module | 2km Single Mode\u003c\/h2\u003e\n\u003cp\u003e800G OSFP FR8, also known as 2×FR4, is a high-performance single-mode transceiver compliant with IEEE 802.3df and OSFP MSA standard. It supports breakout to 2×400G FR4 independent links over dual duplex LC OS2 single-mode fiber, up to 2km, designed for switch-to-switch interconnection in data centers and AI fabrics.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%; font-weight:bold;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eOSFP (Finned-top \/ IHS Twin-port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eRate\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e800G (8×106.25Gbps PAM4), support 2×400G FR4 breakout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eFiber Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle Mode OS2 (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eReach\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDual CWDM4: 1271,1291,1311,1331 nm × 2 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDual Duplex LC UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e≤16.5W (final value subject to supplier datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0℃ ~ 70℃ (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.3df, OSFP MSA Rev 5.0, CMIS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eCompatibility Notice (Important)\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eForm Factor: OSFP (Finned-top, twin-port, IHS)\u003c\/li\u003e\n\u003cli\u003eDesigned for NVIDIA Spectrum-4 SN5600 \/ SN5610 and other twin-port OSFP Ethernet switches supporting 2×400G FR4 profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOT compatible with NVIDIA ConnectX-8 host adapters\u003c\/strong\u003e — ConnectX-8 uses single-port RHS OSFP cages and requires single-port modules such as DR4\u003c\/li\u003e\n\u003cli\u003eCompatible with Arista, Cisco, Juniper and other twin-port OSFP switches; compatibility with third-party optics depends on switch firmware\u003c\/li\u003e\n\u003cli\u003eSupport breakout mode: 800G ↔ 2×400G FR4\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eCore Advantages\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eCost-efficient 2km switch-to-switch DCI solution with dual 400G breakout capability\u003c\/li\u003e\n\u003cli\u003eDual duplex LC interface, simple cabling, fewer fiber cores compared to parallel MPO modules\u003c\/li\u003e\n\u003cli\u003eRetimed PAM4 DSP design, stable link budget for AI fabric interconnection\u003c\/li\u003e\n\u003cli\u003eSupport VDM, digital diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eInteroperable with IEEE standard compliant equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eAI data center switch fabric interconnection, hyperscale data center DCI, 800G \/ 2×400G Ethernet links between twin-port OSFP switches, cloud computing, high-performance computing.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module MPO interface?\u003c\/strong\u003e\u003cbr\u003eA: No. 800G OSFP FR8 (2×FR4) uses Dual Duplex LC UPC connector, not MPO. Please match dual duplex LC OS2 single-mode patch cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it run 2×400G FR4?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports breakout into two independent 400G FR4 channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I plug this IHS twin-port OSFP FR8 into ConnectX-8 NIC?\u003c\/strong\u003e\u003cbr\u003eA: No. Twin-port IHS modules physically cannot fit into ConnectX-8 single-port RHS cages. ConnectX-8 requires single-port RHS modules such as DR4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it work on NVIDIA Spectrum switches?\u003c\/strong\u003e\u003cbr\u003eA: It follows IEEE 802.3df standard. It targets Spectrum-4 twin-port OSFP platforms. Compatibility depends on switch firmware enabling third-party optics.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Skyward Telecom","offers":[{"title":"Default Title","offer_id":53726102257962,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/4948\/9450\/files\/8_e80e00a8-186b-46e6-a1cf-30359bff0189.webp?v=1795506392"},{"product_id":"800g-osfp224-dr4-transceiver-500m","title":"800GBASE-DR4 OSFP224 Transceiver, 1310nm, MPO-12 APC, 500m OS2 SM for ConnectX-8 SuperNIC","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; color:#333; line-height:1.6;\"\u003e\n\u003ch2 style=\"color:#222; border-bottom:1px solid #eee; padding-bottom:8px;\"\u003e800G OSFP224 DR4 Optical Transceiver Module | 500m Single Mode\u003c\/h2\u003e\n\u003cp\u003e800G OSFP224 DR4 is a high-performance single-port RHS flat-top transceiver compliant with IEEE 802.3dj and OSFP224 MSA standard. It runs 4×200G PAM4 parallel channels at 1310nm over OS2 single-mode fiber, up to 500m, purpose-built for NVIDIA ConnectX-8 SuperNIC host adapter uplink in AI GPU clusters.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%; font-weight:bold;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eOSFP224 (RHS \/ Flat-Top, Single-port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eRate\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e800G (4×200Gbps PAM4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eFiber Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle Mode OS2 (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f7f7f7; border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eReach\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e500 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMPO-12 APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e≤16W (final value subject to supplier datasheet; NVIDIA OEM MMS4A20 max 18W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0℃ ~ 70℃ (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.3dj, OSFP224 MSA, CMIS 5.3 (subject to supplier firmware)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eCompatibility Notice (Important)\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eForm Factor: OSFP224 RHS Flat-Top, single-port module\u003c\/li\u003e\n\u003cli\u003eDesigned for NVIDIA ConnectX-8 SuperNIC C8180\/C8240 series single-port OSFP224 RHS cage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOT compatible with twin-port IHS finned-top OSFP switch cages\u003c\/strong\u003e (Spectrum \/ Quantum twin-port switches)\u003c\/li\u003e\n\u003cli\u003eCompatible with NVIDIA ConnectX-8 SuperNIC (C8180\/C8240 series). For third-party modules, please confirm firmware version and whitelist policy before ordering.\u003c\/li\u003e\n\u003cli\u003eSupport 800G Ethernet and InfiniBand XDR mode, subject to NIC firmware configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eCore Advantages\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eNative 4×200G PAM4 parallel design for 500m short-reach single-mode links\u003c\/li\u003e\n\u003cli\u003eMPO-12 APC interface, low return loss for stable single-mode transmission\u003c\/li\u003e\n\u003cli\u003eIntegrated DSP retimer, built-in VDM \/ digital diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eLow power RHS flat-top thermal design for NIC side deployment\u003c\/li\u003e\n\u003cli\u003eInteroperable with IEEE standard compliant fabrics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eAI GPU cluster host uplink, server-to-switch interconnection, 800G XDR InfiniBand \/ 800GbE links for ConnectX-8 SuperNIC, high-performance computing.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this twin-port IHS module for Spectrum switches?\u003c\/strong\u003e\u003cbr\u003eA: No. This is single-port RHS flat-top OSFP224 DR4, made for ConnectX-8 SuperNIC. It physically cannot fit into twin-port IHS switch cages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What fiber patch cord should I use?\u003c\/strong\u003e\u003cbr\u003eA: OS2 single-mode MPO-12 APC trunk cable, match the APC polishing to avoid high return loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it work as InfiniBand XDR?\u003c\/strong\u003e\u003cbr\u003eA: Yes, 800G XDR is supported when ConnectX-8 SuperNIC firmware is configured for InfiniBand mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support breakout?\u003c\/strong\u003e\u003cbr\u003eA: This DR4 is 4×200G parallel fixed channel, not breakout to independent 400G links.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Skyward Telecom","offers":[{"title":"Default Title","offer_id":53728609829162,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/4948\/9450\/files\/8_aa978810-8ee1-465c-a017-faa868ab69dd.webp?v=1795509021"},{"product_id":"1-6t-osfp224-2xdr4-transceiver-500m","title":"1.6TBASE 2×DR4 DR8 OSFP224 Transceiver, 1310nm, Dual MPO-12 APC, 500m OS2 for AI Fabric Switches","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif; color:#333; line-height:1.6;\"\u003e\n\u003ch2 style=\"color:#222; border-bottom:1px solid #eee; padding-bottom:8px;\"\u003e1.6T OSFP224 2×DR4 Optical Transceiver Module | 500m Single Mode\u003c\/h2\u003e\n\u003cp\u003e1.6T OSFP224 2×DR4 (also known as DR8) is a high-density twin-port switch-side transceiver compliant with IEEE 802.3dj and OSFP224 MSA standard. It operates 8×200Gbps PAM4 parallel lanes at 1310nm over OS2 single-mode fiber up to 500m, supporting breakout into two independent 800G DR4 channels for AI fabric spine-leaf interconnection.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%; font-weight:bold;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eOSFP224 Twin-port (IHS \/ Finned-top, switch-side only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eRate\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1.6T (8×200Gbps PAM4), support breakout to 2×800G DR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eFiber Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle Mode OS2 (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eReach\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e500 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDual MPO-12 APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e≤25W (final value subject to supplier datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0℃ ~ 70℃ (Commercial Grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; font-weight:bold;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.3dj, OSFP224 MSA, CMIS 5.2\/5.3 (subject to supplier firmware)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eCompatibility Notice (Important)\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eForm Factor: OSFP224 Twin-port IHS Finned-top, designed for switch-side IHS cages only\u003c\/li\u003e\n\u003cli\u003ePrimary platform: NVIDIA Quantum-X800 InfiniBand and Spectrum-X Ethernet OSFP224 switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOT compatible with NVIDIA ConnectX-9 SuperNIC directly\u003c\/strong\u003e: ConnectX-9 uses single-port RHS OSFP224 cages and requires single-port 800G DR4 modules (e.g., MMS4A20)\u003c\/li\u003e\n\u003cli\u003eThe 2×800G breakout outputs from this module can connect to two separate ConnectX-9 SuperNICs via fiber patch cords, but the module itself must be installed in a switch IHS cage\u003c\/li\u003e\n\u003cli\u003eFor third-party modules, please confirm switch firmware version and optics whitelist policy before ordering\u003c\/li\u003e\n\u003cli\u003eSupport breakout mode: 1.6T ↔ 2×800G DR4\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eCore Advantages\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003eHigh density 1.6T port with native 2×800G breakout, saving switch port count in AI clusters\u003c\/li\u003e\n\u003cli\u003eDual MPO-12 APC interface, low return loss for stable single-mode parallel transmission\u003c\/li\u003e\n\u003cli\u003eIntegrated DSP retimer, built-in VDM \/ digital diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eIHS finned-top thermal design optimized for switch-side high-density deployment\u003c\/li\u003e\n\u003cli\u003eInteroperable with IEEE 802.3dj standard compliant fabrics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eAI GPU cluster spine-leaf interconnection, 1.6T switch fabric, 2×800G DR4 breakout links from Quantum-X800 \/ Spectrum-X switches to ConnectX-9 SuperNICs, hyperscale data center interconnection, high-performance computing.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:24px;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I plug this module into a ConnectX-9 SuperNIC and run 1.6T?\u003c\/strong\u003e\u003cbr\u003eA: No. This is an IHS finned-top switch-side module, it cannot fit into ConnectX-9 single-port RHS NIC cages. ConnectX-9 supports maximum 800G per port and requires single-port RHS 800G DR4 modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the 2×800G breakout connect to ConnectX-9 NICs?\u003c\/strong\u003e\u003cbr\u003eA: The module must be installed in a Quantum-X800 or compatible switch IHS cage first. Its two 800G DR4 breakout channels then connect to two separate ConnectX-9 SuperNICs via MPO single-mode patch cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What fiber patch cord should I use?\u003c\/strong\u003e\u003cbr\u003eA: OS2 single-mode MPO-12 APC trunk cables, match APC polishing to avoid high return loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this IHS module compatible with RHS NIC cages?\u003c\/strong\u003e\u003cbr\u003eA: No. IHS finned-top modules and RHS flat-top modules are physically incompatible; do not attempt installation across cage types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support InfiniBand?\u003c\/strong\u003e\u003cbr\u003eA: Yes, compatible with XDR InfiniBand when used with Quantum-X800 and matching firmware configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Skyward Telecom","offers":[{"title":"Default Title","offer_id":53729450754346,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/4948\/9450\/files\/9_4be19962-1be2-4fc2-a52c-306fd2dd16b1.webp?v=1795510816"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/4948\/9450\/collections\/10_37828c1f-914d-44ff-ae18-97e2e5ca7429.webp?v=1795435480","url":"https:\/\/skyward-telecom.com\/ar\/collections\/800g-optical-transceivers.oembed","provider":"Skyward Telecom","version":"1.0","type":"link"}